All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.

Authors

An intravesical exposed mesh may result from an unrecognized bladder perforation or from bladder erosion after a mid-urethral sling procedure performed to treat a stress urinary incontinence. Introduction of trans-obturator tape and tension-free vaginal tape-obturator techniques have minimized, but not eliminated, the risk of bladder injury. The suggested management of the above complication is removal of the polypropylene mesh from the bladder. Herein, we describe a case of partial intravesically-exposed sling, first diagnosed by trans-labial ultrasound, confirmed by cystourethroscopy and successful treated with endoscopic transurethral resection.