The use of a new automatic device for patients' assessment at Triage in Emergency Department

Chiara Serena Gori, Benedetta De Bernardinis, Daniele Salvatori, Daniele De Nuzzo, Caterina Tranne, Enrico Ferri, Salvatore Di Somma
  • Chiara Serena Gori
    Emergency Department, Second Medical School, Sapienza University of Rome, Sant’Andrea Hospital, Rome, Italy., | lucia.zoppi@pagepress.org
  • Benedetta De Bernardinis
    Emergency Department, Second Medical School, Sapienza University of Rome, Sant’Andrea Hospital, Rome, Italy.,
  • Daniele Salvatori
    Emergency Department, Second Medical School, Sapienza University of Rome, Sant’Andrea Hospital, Rome, Italy.,
  • Daniele De Nuzzo
    Emergency Department, Second Medical School, Sapienza University of Rome, Sant’Andrea Hospital, Rome, Italy.,
  • Caterina Tranne
    Emergency Department, Second Medical School, Sapienza University of Rome, Sant’Andrea Hospital, Rome, Italy.,
  • Enrico Ferri
    Emergency Department, Second Medical School, Sapienza University of Rome, Sant’Andrea Hospital, Rome, Italy.,
  • Salvatore Di Somma
    Emergency Department, Second Medical School, Sapienza University of Rome, Sant’Andrea Hospital, Rome, Italy.,

Abstract

Objectives: To assess time saving in an Emergency Department arising out of the introduction of automatic devices (Carescape™ V100) to measure vital signs compared to the manual devices. Methods: We performed a prospective, observational study of eligible patients referring to Sant’Andrea Hospital Emergency Department during the entire month of October 2009, randomly assigned into two groups. In the first group of 476 patients vital signs measurements were detected with manual devices, while in the second group of 477 patients with automatic device Carescape™ V100. Results: Data indicated that the comparison of the total time between the two groups gave a significant difference (1993 vs 1518 min, p < 0.001). No differences were found with respect to age, sex and priority codes. Significant differences were also found when comparing the subgroups of the same acuity categories: white codes 4.33 vs 2.27 (min), p < 0.05; green codes 4.28 vs 3.37 (min), p < 0.001; yellow codes 3.92 vs 2.72 (min), p < 0.001. Conclusions: Our data demonstrated a statistical significance between the two groups with a difference of 475 minutes spent in Triage procedures including vital signs measurements. In conclusion time saved by vital signs automatic device could allow ED physicians to make a qualified approach with an earlier diagnosis and a more rapid and effective therapy, possibly improving patients’ outcomes. ABSTRACT of data concerning vital signs quality assessment, because we did not compare the two methods in the same patient and we did not correlate Triage priority evaluation with patients’ outcomes. In the future further studies should be specifically aimed to address this issue. In conclusion time saved by vital signs automatic device could allow ED physicians to make a qualified approach to patient with an earlier diagnosis and a more rapid and effective therapy, possibly improving patients’ outcomes.

Keywords

Emergency Department; Triage

Full Text:

PDF
Submitted: 2013-02-17 10:08:49
Published: 2010-06-10 00:00:00
Search for citations in Google Scholar
Related articles: Google Scholar
Abstract views:
655

Views:
PDF
577

Article Metrics

Metrics Loading ...

Metrics powered by PLOS ALM




Copyright (c) 2010 Chiara Serena Gori, Benedetta De Bernardinis, Daniele Salvatori, Daniele De Nuzzo, Caterina Tranne, Enrico Ferri, Salvatore Di Somma

Creative Commons License
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
 
© PAGEPress 2008-2018     -     PAGEPress is a registered trademark property of PAGEPress srl, Italy.     -     VAT: IT02125780185